Parameter list
Parameters
1-137
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets a value for the fixed speed / velocity setpoint 8.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 12.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fixed 12
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]