Parameters
Parameter list
1-62
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the power module fan operating hours.
The number of hours operated can only be reset to 0 in this parameter (e.g. after a fan has been replaced).
Dependency:
Refer to: p0252
Description:
Sets the maximum operating time of the power module fan.
The pre-alarm (warning) is output 500 hours before this set value.
The monitoring is de-activated with p0252 = 0.
Dependency:
Refer to: p0251
Description:
Sets the shutdown threshold for the ground fault monitoring.
The setting is made as a percentage of the maximum power module current (r0209).
Index:
[0] = Threshold for pulse inhibit
[1] = Threshold for pulse enable
Note:
The ground fault monitoring is de-activated by initially setting index 1 to 0 and then by setting index 0 to 0.
Description:
Displays the actual, maximum output current of the power module taking into account de-rating factors.
p0251[0...n]
Operating hours counter, power module fan / PM fan t_oper
VECTOR
Can be changed:
T
Access level:
4
Data type:
Unsigned32
Data set:
PDS
Function diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 4294967295
0
p0252
Maximum operating time, power module fan / PM fan t_oper max
VECTOR
Can be changed:
T
Access level:
4
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 50000
40000
p0287[0...1]
Ground fault monitoring, thresholds / Grnd fault, thresh
VECTOR
Can be changed:
T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
-
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.0 [%]
100.0 [%]
[0] 6.0 [%]
[1] 16.0 [%]
r0289
Maximum power module output current / PM I_output max
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]