Parameters
Parameter list
1-138
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets a value for the fixed speed / velocity setpoint 13.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 14.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 15.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets the signal source to select the speed/velocity fixed setpoint.
Dependency:
Selects the required fixed speed setpoint using p1020 ... p1023.
Displays the number of the actual fixed speed setpoint in r1197.
Sets a value for the fixed speed setpoints 1 ... 15 using p1001 ... p1015.
Refer to: p1021, p1022, p1023, r1197
Note:
If a fixed speed setpoint has not been selected (p1020 ... p1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
Description:
Sets the signal source to select the speed/velocity fixed setpoint.
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fixed 13
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fixed 14
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1015[0...n]
CO: Fixed speed setpoint 15 / n_set_fixed 15
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1020[0...n]
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
2505
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1021[0...n]
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
2505
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0