![Siemens SINAMICS G List Manual Download Page 54](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180054.webp)
Parameters
Parameter list
1-54
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the version of the EPROM data of the terminal module.
Dependency:
Refer to: r0127, r0147
Description:
Displays the terminal module firmware version.
Dependency:
Refer to: r0018, r0128, r0148, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Sets the component number for the option board (e.g. terminal board 30).
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to an option board.
Description:
Sets the number of command data sets (CDS).
Note:
It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
Description:
Sets the number of drive data sets (DDS).
Note:
It is possible to toggle between open-loop and closed-loop control parameters using this data set changeover.
r0157
Terminal module version EPROM data / TM Eep_version
TM31
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r0158
Terminal module firmware version / TM FW_version
TM31
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0161
Option board, component number / OptBoard comp_no
TB30
Can be changed:
C1
Access level:
4
Data type:
Unsigned8
Data set:
-
Function diagram:
9100
P-Group:
Data sets
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 199
0
p0170
Command Data Set (CDS) number / CDS quantity
VECTOR
Can be changed:
C1
Access level:
2
Data type:
Unsigned8
Data set:
-
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
1 2
1
p0180
Drive Data Set (DDS) number / DDS quantity
VECTOR
Can be changed:
C1
Access level:
2
Data type:
Unsigned8
Data set:
-
Function diagram:
8565
P-Group:
Data sets
Units group:
-
Unit selection:
-
Min Max
Factory
setting
1 32
1