Parameters
Parameter list
1-314
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the second amplitude for the signal to be generated for the function generator.
Dependency:
Only effective for p4820 = 2 (staircase).
Units are dependent on p4810.
If p4810 = 1, 2, 4: the amplitude is referred to p2002 (rated motor current).
If p4810 = 3, 5: the amplitude is referred to p2000 (rated motor speed).
Description:
Sets the offset (DC component) of the signal to be generated for the function generator.
Dependency:
Units are dependent on p4810.
If p4810 = 1, 2, 4: the offset is referred to p2002 (rated motor current).
If p4810 = 3, 5: the offset is referred to p2009 (rated motor speed).
If p4810 = 2: in order to avoid effects of play (backlash), the offset does not act on the current setpoint, but instead
on the speed setpoint.
Description:
Sets the ramp-up time to the offset for the function generator.
Description:
Sets the lower limit for the function generator.
Dependency:
For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description:
Sets the upper limit for the function generator.
p4825
Function generator 2nd amplitude / FG 2nd amplitude
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-1600.00 [%]
1600.00 [%]
7.00 [%]
p4826
Function generator offset / FG offset
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-1600.00 [%]
1600.00 [%]
0.00 [%]
p4827
Function generator ramp-up time to offset / FG ramp-up offset
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.00 [ms]
100000.00 [ms]
32.00 [ms]
p4828
Function generator lower limit / FG lower limit
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-10000.00 [%]
0.00 [%]
-100.00 [%]
p4829
Function generator upper limit / FG upper limit
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.00 [%]
10000.00 [%]
100.00 [%]