Parameters for data sets
Parameters
1-363
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG
p1140[0...n]
BI: Enables the ramp-function generator / Enable RFG
p1141[0...n]
BI: Start ramp-function generator / Start RFG
p1142[0...n]
BI: Enable speed setpoint / Enable n_set
p1143[0...n]
BI: Ramp-function generator, accept setting value / Accept RFG set val
p1144[0...n]
CI: Ramp-function generator setting value / RFG setting value
p1155[0...n]
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
p1160[0...n]
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
p1330[0...n]
CI: V/Hz control independent voltage setpoint / Uf U_set independ.
p1437[0...n]
CI: Speed controller, reference model I component input / n_ctrRefMod I_comp
p1455[0...n]
CI: Speed controller P gain adaptation signal / n_ctrl Adpt_sig Kp
p1466[0...n]
CI: Speed controller P-gain scaling / n_ctrl Kp Scal
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
p1478[0...n]
CI: Speed controller integrator setting value / n_ctr integ_setVal
p1479[0...n]
CI: Speed controller integrator setting value scaling / n_ctrl I_val scal
p1492[0...n]
BI: Droop feedback enable / Enables droop
p1495[0...n]
CI: Acceleration pre-controlling, speed change each 1 s / a_prectrl dn/1s
p1500[0...n]
Macro connector inputs (CI) for torque setpoints / Macro CI M_set
p1501[0...n]
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
p1503[0...n]
CI: Torque setpoint / M_set
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
p1522[0...n]
CI: Torque limit, upper/motoring / M_max upper/mot
p1523[0...n]
CI: Torque limit, lower/regenerative / M_max lower/regen
p1528[0...n]
CI: Torque limit upper scaling / M_max upper scal
p1529[0...n]
CI: Torque limit lower scaling / M_max lower scal
p1540[0...n]
CI: Torque limit upper scaling / M_max upper scal
p1541[0...n]
CI: Torque limit lower scaling / M_max lower scal
p2103[0...n]
BI: 1. Acknowledge faults / 1. Acknowledge
p2104[0...n]
BI: 2. Acknowledge faults / 2. Acknowledge
p2105[0...n]
BI: 3. Acknowledge faults / 3. Acknowledge
p2106[0...n]
BI: External fault 1 / External fault 1
p2107[0...n]
BI: External fault 2 / External fault 2
p2108[0...n]
BI: External fault 3 / External fault 3
p2112[0...n]
BI: External alarm 1 / External alarm 1
p2116[0...n]
BI: External alarm 2 / External alarm 2
p2117[0...n]
BI: External alarm 3 / External alarm 3
p2148[0...n]
BI: Ramp-function generator active / HLG active
p2151[0...n]
CI: Speed setpoint for messages/signals / n_set for msg
p2154[0...n]
CI: Speed setpoint 2 / n_set 2
p2200[0...n]
BI: Technology controller enable / Tec_ctr enable
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctr sel bit 0
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctr sel bit 1
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctr sel bit 2
p2223[0...n]
BI: Technology controller fixed value selection bit 3 / Tec_ctr sel bit 3
p2235[0...n]
BI: Technology controller motorized potentiometer, raise setpoint / Tec_ctr mop raise
p2236[0...n]
BI: Technology controller motorized potentiometer, lower setpoint / Tec_ctr mop lower
p2253[0...n]
CI: Technology controller setpoint 1 / Tec_ctr setpoint 1
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctr setpoint 2
p2264[0...n]
CI: Technology controller actual value / Tec_ctr act val
p2289[0...n]
CI: Technology controller pre-control signal / Tec_ctr prectrl