Parameter list
Parameters
1-77
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the stator direct axis inductance of the motor for synchronous motors.
This parameter value is automatically calculated using the motor model (p0340 = 1, 2) or using the motor identifica-
tion routine (p1910).
Description:
Sets the rotor/secondary section leakage inductance of the motor.
The value is automatically calculated using the motor model (p0340 = 1, 2) or determined using the motor identifica-
tion routine (p1910).
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
The parameter is automatically preset for motors from the motor list (p0301).
Description:
Sets the magnetizing inductance of the motor.
This parameter value is automatically calculated using the motor model (p0340 = 1, 2) or using the motor identifica-
tion routine (p1910).
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
The parameter is automatically preset for motors from the motor list (p0301).
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the y coordinate (flux) for the 1st value pair of the characteristic.
Sets the first flux value of the saturation characteristic as a [%] referred to the rated motor voltage (p0304).
Dependency:
The following applies for the flux values:
p0362 < p0363 < p0364 < p0365
Refer to: p0366
Note:
p0362 = 100 % corresponds to the rated motor flux.
p0357[0...n]
Motor stator inductance, d axis / Mot L_stator_d
VECTOR
Can be changed:
C2, T
Access level:
3
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
INDUCTANCE_M3
Unit selection:
-
Min Max
Factory
setting
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0358[0...n]
Motor rotor leakage inductance / Mot L_rotor leak.
VECTOR
Can be changed:
C2, U, T
Access level:
3
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
INDUCTANCE_M3
Unit selection:
-
Min Max
Factory
setting
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0360[0...n]
Motor magnetizing inductance / Mot L_main
VECTOR
Can be changed:
C2, U, T
Access level:
3
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
INDUCTANCE_M3
Unit selection:
-
Min Max
Factory
setting
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
p0362[0...n]
Saturation characteristic flux 1 / Mot saturat.flux 1
VECTOR
Can be changed:
C2, U, T
Access level:
4
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
25.0 [%]
300.0 [%]
60.0 [%]