Parameter list
Parameters
1-53
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Detects the sensor module assigned to this drive and data set.
Note:
While p0144 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate sensor module.
Description:
Displays the version of the EPROM data of the sensor module.
Dependency:
Refer to: r0127, r0157
Description:
Displays the sensor module firmware version.
Dependency:
Refer to: r0018, r0128, r0158, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Sets the component number for the terminal module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a terminal module.
Description:
Detects the terminal module assigned to this drive and data set.
Note:
While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate terminal mod-
ule.
p0144[0...n]
Sensor module detection via LED / SM detection LED
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Unsigned8
Data set:
EDS
Function diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
r0147[0...n]
Sensor module version EPROM data / SM Eep_version
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
EDS
Function diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r0148[0...n]
Sensor module firmware version / SM FW_version
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
EDS
Function diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0151
Terminal module component number / TM comp_no
TM31
Can be changed:
C1
Access level:
4
Data type:
Unsigned8
Data set:
-
Function diagram:
9550,
9552
P-Group:
Data sets
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 199
0
p0154
Terminal module detection via LED / TM detection LED
TM31
Can be changed:
U, T
Access level:
2
Data type:
Unsigned8
Data set:
-
Function diagram:
-
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0