![Siemens SINAMICS G List Manual Download Page 180](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180180.webp)
Parameters
Parameter list
1-180
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
Re bit 01:
When the bit is set, the I component of the speed controller is kept when changing into the open-loop controlled
mode.
Description:
Sets the configuration for flux setpoint control
Description:
Displays the control word of the speed controller.
Description:
Displays the status word of the speed controller.
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Automatic Kp/Tn adaptation active
No
Yes
-
01
Sensorless closed-loop vector ctrl freeze I
comp
No
Yes
-
02
Acceleration pre-control source
Internal (n_set)
External (p1495)
6031
03
Reference model speed setpoint, I compo-
nent
Off
On
-
05
Kp/Tn adaptation active
No
Yes
-
06
Free Tn adaptation active
No
Yes
-
14
Torque pre-control
For n_ref ctr enab
Always active
-
15
Sensorless closed-loop vector ctrl speed
prectrl
No
Yes
-
p1401[0...n]
Flux control configuration / F_ctrl config
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
DDS
Function diagram:
6491,
6722
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
0111 bin
0110 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Flux setpoint soft starting active
No
Yes
-
01
Flux setpoint differentiation active
No
Yes
-
02
Flux build-up control active
No
Yes
-
r1406
CO/BO: Control word speed controller / STW n_ctrl
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
04
Holds speed controller I component
No
Yes
-
05
Sets speed controller I component
No
Yes
-
11
Enables droop
No
Yes
6030
12
Torque control active
No
Yes
-
r1407
CO/BO: Status word speed controller / ZSW n_ctrl
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2522
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-