Parameters
Parameter list
1-162
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the signal source for the feedback signal "brake open".
For motor holding brakes with feedback signal, the signal "brake open" can be activated using p1275.5 = 1.
Dependency:
Refer to: p1222, p1275
Note:
1 signal: Brake open.
When braking with 1 feedback signal, the inverted feedback signal is connected to the BICO input for the second
feedback signal (p1222).
Description:
Sets the signal source for close brake at standstill.
Dependency:
Refer to: p1275
Note:
[0]: Signal, close brake at standstill, inversion via p1275.2
[1]: Signal, close brake at standstill, inversion via p1275.3
[2]: Signal, close brake at standstill
[3]: Signal, close brake at standstill
These four signals form an OR logic operation.
Description:
Sets the signal source "threshold value" for the standstill identification.
Dependency:
Refer to: p1226, p1228, r1229
Description:
Sets the speed/velocity threshold for the standstill identification.
Acts on the actual value and setpoint monitoring.
When braking with OFF1 or OFF3, when the threshold is fallen below, standstill is identified.
The following applies when the brake control is activated:
When the threshold is fallen below, the brake control is started and the system waits for the brake closing time in
p1217. The pulses are then canceled.
if the brake control is not activated, the following applies:
When the threshold is fallen below, the pulses are cancelled and the drive coasts down.
p1223
BI: Motor holding brake, feedback signal, brake open / Brake feedb open
VECTOR (Extended
brk)
Can be changed:
T
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
2711
P-Group:
Functions
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
1
p1224[0...3]
BI: Close motor holding brake at standstill / Brk close standst
VECTOR (Extended
brk)
Can be changed:
T
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
2704
P-Group:
Functions
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1225
CI: Standstill detection, threshold value / Standstill thresh
VECTOR (Extended
brk)
Can be changed:
T
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
2704
P-Group:
Functions
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
63[0]
p1226
Threshold for zero speed detection / n_standst n_thresh
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
2701
P-Group:
Functions
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.0 [1/min]
210000.0 [1/min]
20.0 [1/min]