Parameter list
Parameters
1-215
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the proportional gain for the Lh adaptation of the motor model of the induction motor.
Description:
Sets the integral action time for the Lh adaptation of the motor model of the induction motor.
Description:
Displays the correction value for the Lh adaptation of the motor model for the induction motor.
Description:
Displays the power-on stator frequency for the Rs adaptation of the induction motor.
Description:
Displays the power-on slip frequency for the Rs adaptation of the induction motor.
Description:
Displays the power-on stator frequency / primary section frequency for the Lh adaptation of the induction motor.
p1785[0...n]
Motor model IM Lh adaptation Kp / MotMod Lh Kp
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0.000 1.000
0.100
p1786[0...n]
Motor model IM Lh adaptation integral action time / MotMod Lh Tn
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
p0528
Min Max
Factory
setting
10 [ms]
10000 [ms]
100 [ms]
r1787
Motor model IM Lh adaptation correction value / MotMod Lh corr
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
INDUCTANCE_M3
Unit selection:
-
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r1789
Motor model IM Rs adaptation switch-on frequency / MotMod Rs f_on
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1790
Motor model IM Rs adaptation switch-on slip / MotMod Rs fslip
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1791
Motor model IM Lh adaptation switch-on frequency / MotMod Lh f_on
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]