Parameter list
Parameters
1-135
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays those parameters with a value other than the factory setting for this drive.
Dependency:
Refer to: r0990, r0991
Note:
Modified parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here.
This list completely comprises the following parameters:
r0990[0...99], r0991[0...99] ... r0999[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
Description:
Runs the appropriate ACX file on the CompactFlash Card.
The connector inputs (CI) for the speed setpoints of the appropriate command data set (CDS) are appropriately
interconnected.
The selected ACX file must be located in the following directory:
... /PMACRO/<drive object>/P1000/PMxxxxxx.ACX
Example:
p1000 = 6 --> the file PM000006.ACX is run.
Dependency:
The ACX file to be run must be created according to the definition for ACX macros and must be saved in the direc-
tory intended on the CompactFlash Card.
Refer to: p0015, p0700, p1500
Note:
CI: Connector input
Description:
Sets a value for the fixed speed / velocity setpoint 1.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Description:
Sets a value for the fixed speed / velocity setpoint 2.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
r0999[0...99]
List of modified parameters 10 / List changd par10
All objects
Can be changed:
-
Access level:
4
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p1000[0...n]
Macro connector inputs (CI) for speed setpoints / Macro CI n_set
VECTOR
Can be changed:
C2, T
Access level:
1
Data type:
Unsigned32
Data set:
CDS
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 999999
0
p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fixed 1
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fixed 2
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
3010
P-Group:
Setpoints
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
-210000.000 [1/min]
210000.000 [1/min]
0.000 [1/min]