Parameter list
Parameters
1-241
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the last parameter received from the PROFIBUS master for clock synchronism.
The parameters for clock synchronism are created when configuring the bus and are transferred at the start of
cyclic operation from the PROFIBUS master to the slave.
Index:
[0] = Clock synchronous mode activated
[1] = Bus cycle time (Tdp) [µs]
[2] = Master cycle time (Tmapc) [µs]
[3] = Instant of actual value acquisition (Ti) [µs]
[4] = Instant of setpoint acquisition (To) [µs]
[5] = Data exchange interval (Tdx) [µs]
[6] = PLL window (Tpll-w) [1/12 µs]
[7] = PLL delay time (Tpll-d) [1/12 µs]
Description:
PZD byte offset in the PROFIBUS receive telegram (master output).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Note:
Value range:
0 - 242: Byte offset
255: Not occupied
Description:
PZD byte offset in the PROFIBUS receive telegram (master output).
r2064[0...7]
PROFIBUS diagnostics clock synchronous mode / PB diag clock sync
CU
Can be changed:
-
Access level:
3
Data type:
Integer32
Data set:
-
Function diagram:
2410
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r2075[0...4]
PROFIBUS diagnostics telegram offset PZD receive / PB diag offs recv
CU, TB30, TM31
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r2075[0...15]
PROFIBUS diagnostics telegram offset PZD receive / PB diag offs recv
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-