Parameter list
Parameters
1-155
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the number of the selected fixed speed/velocity setpoint.
Dependency:
Refer to: p1020, p1021, p1022, p1023
Note:
If a fixed speed setpoint has not been selected (p1020 ... p1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
Description:
Displays the control word for the setpoint channel.
Description:
Displays the status word for the ramp-function generator (RFG).
Note:
Re bit 02:
The bit is an OR logic operation - bit 00 and bit 01.
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Interpolation ramp-fct gen/speed controller
active
No
Yes
3080
01
Interpol. op-loop ctrl /speed controller active No
Yes
3080
r1197
Fixed speed setpoint, actual number / n_set_fixed No act
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
3010
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r1198
CO/BO: Control word setpoint channel / STW setpoint chan
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2505
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Fixed setp. bit 0
No
Yes
-
01
Fixed setp. bit 1
No
Yes
-
02
Fixed setp. bit 2
No
Yes
-
03
Fixed setp. bit 3
No
Yes
-
05
Inhibit negative direction
No
Yes
-
06
Inhibit positive direction
No
Yes
-
11
Direction reversal
No
Yes
-
13
Motorized potentiometer, raise
No
Yes
-
14
Motorized potentiometer, lower
No
Yes
-
15
Bypass ramp-function generator
No
Yes
-
r1199
CO/BO: Ramp-function generator status word / RFG ZSW
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
1550,
3080, 8010
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Ramp-up active
No
Yes
-
01
Ramp-down active
No
Yes
-
02
Ramp-function generator active
No
Yes
-
03
Ramp-function generator set
No
Yes
-
04
Ramp-function generator held
No
Yes
-
05
Ramp-function generator tracking active
No
Yes
-
06
Maximum limit active
No
Yes
-