Parameters
Parameter list
1-204
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the denominator damping for current setpoint filter 1.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the numerator natural frequency for current setpoint filter 1 (general filter).
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the numerator damping for current setpoint filter 1.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the current setpoint filter 2 as low pass (PT2) or as extended general 2nd-order filter.
Values:
1:
Low pass: PT2
2:
General 2nd-order filter
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Note:
For an extended general 2nd order filter, by inserting the same natural frequency in both the numerator and in the
denominator, i.e. bandstop frequency, a bandstop filter is implemented. If the numerator damping of zero is
selected, the bandstop frequency is completely suppressed. The numerator damping can be determined from the
equation for the 3 dB bandwidth: f_3dB bandwidth = 2 * D_numerator * f_bandstop frequency.
p1659[0...n]
Current setpoint filter 1 denominator damping / I_set_filt 1 D_n
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5710,
6710
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0.001 10.000
0.700
p1660[0...n]
Current setpoint filter 1 numerator natural frequency / I_set_filt 1 fn_z
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5710,
6710
P-Group:
Control
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
1999.0 [Hz]
p1661[0...n]
Current setpoint filter 1 numerator damping / I_set_filt 1 D_z
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5710,
6710
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0.000 10.000
0.700
p1662[0...n]
Current setpoint filter 2 type / I_set_filt 2 Typ
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Data set:
DDS
Function diagram:
5710,
6710
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
1 2
1