7.2.2 Changing the Y-axis mechanical stopper position
The Y-axis mechanical stopper position is changed by installing the supplied parts.
■
Supplied parts
R6YXG500, R6YXG600
No.
Part No.
Q'ty
Remarks (supplied)
Additional mechanical stopper parts in either one direction
of Y-axis plus or minus direction (*1)
1
KbF-m1123-001
1
Washer (*2)
2
91312-08016
1
Bolt
R6YXGS500, R6YXGS600
No.
Part No.
Q'ty
Remarks (supplied)
Additional mechanical stopper parts in either one direction
of Y-axis plus or minus direction (*1)
1
KbF-m1123-001
2
Washer (*2)
2
91312-08016
2
Bolt
*1 : Since the X-axis has two stoppers as standard, no additional stopper will be needed for changing the X-axis stopper position.
To change the Y-axis stopper position in the plus or minus direction or even in both directions, use one each of the above stopper parts.
(When the stopper in both directions is added, the existing stopper is also used after moving it.)
*2 : Washers are also used when moving the robot using the eyebolts. After having moved the robot, use the washers to change the stopper
position.
If the washers are needed again to move the robot using the eyebolts, remove the washers from the stopper and then place them underneath
the eyebolts.
R6YXGH600, R6YXG700, R6YXG800, R6YXG900, R6YXG1000
No.
Part No.
Q'ty
Remarks (supplied)
Additional mechanical stopper parts in either one direction
of Y-axis plus or minus direction (*1)
1
Kbp-m1123-001
2
Washer (*2)
2
90112-10J025
1
Bolt
R6YXGS700, R6YXGS800, R6YXGS900, R6YXGS1000
No.
Part No.
Q'ty
Remarks (supplied)
Additional mechanical stopper parts in either one direction
of Y-axis plus or minus direction (*1)
1
Kbp-m1123-001
4
Washer (*2)
2
90112-10J025
2
Bolt
*1 : Since the X-axis has two stoppers as standard, no additional stopper will be needed for changing the X-axis stopper position.
To change the Y-axis stopper position in the plus or minus direction or even in both directions, use one each of the above stopper parts.
(When the stopper in both directions is added, the existing stopper is also used after moving it.)
*2 : Washers are also used when moving the robot using the eyebolts. After having moved the robot, use the washers to change the stopper
position.
If the washers are needed again to move the robot using the eyebolts, remove the washers from the stopper and then place them underneath
the eyebolts.
Summary of Contents for R6YXG500
Page 1: ...ZX T Series Cat No I155E EN 03A R6Y XG series INSTALLATION MANUAL SCARA Robots XG Series...
Page 2: ......
Page 10: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 46: ......
Page 48: ......
Page 56: ......
Page 174: ......
Page 176: ......
Page 220: ......
Page 221: ...Chapter 4 Periodic inspection Contents 1 Overview 4 1 2 List of inspection items 4 2...
Page 222: ......
Page 226: ......
Page 227: ...Chapter 5 Harmonic drive replacement period Contents 1 Overview 5 1 2 Replacement period 5 2...
Page 228: ......
Page 232: ......
Page 238: ......
Page 240: ......
Page 244: ......
Page 246: ......
Page 323: ...8 Specifications 8 77 1 3 Robot inner wiring diagram Robot inner wiring diagram R6YXG500...