Robot settings
3-6
6
Perform the absolute reset.
The absolute reset execution confirmation screen
pops up.
check that there are no obstacles within the
movement range, and then press
. to cancel the
absolute reset, press
. After the absolute reset
has been completed, press
to return to the
"ORIGIN RTN (TRQ/SENS)" screen.
$EVROXWHUHVHW
6WHS
7
Check the machine reference value.
“Status” and “Ref.” (machine reference) are
displayed on the "ORIGIN RTN (TRQ/SENS)"
screen.
Check that the status is "OK" and that the machine
reference value is within the absolute reset tolerable
range (25 to 75%).
■
Machine reference value checking procedure
1. use the cursor keys (
/
) on the initial screen to select operation and press
to display the operation
menu.
2. Select origin return and press
to display the “ORIGIN RTN (TRQ/SENS)" screen. The absolute reset completion
status and machine reference are then displayed.
If the machine reference value is beyond the absolute reset tolerable range, the next absolute reset may not be performed
correctly.
In this case, make the adjustment while referring to "2. Adjusting the origin" in this Chapter.
2.3.2 Stroke end method (Z-axis) with YRCX controller
WARning
SeriouS injury may occur from phySical contact with the robot during operation. never enter
within the robot movement range during abSolute reSet.
the operation procedure using the pbeX is described below.
nOTE
• When pressing the
key on the execution confirmation screen, the execution of the absolute reset is canceled.
• For details about how to operate the robot controller, see the "OMRON Robot Controller User's Manual".
1
Turn on the controller.
Check that no one is inside the safety enclosure, and
then turn on the controller.
2
Place a sign indicating the robot is
being adjusted.
Place a sign indicating the robot is being adjusted, to
keep others from operating the controller or operation
panel.
3
Display the "ORIGIN RTN (TRQ/
SENS)" screen on the PBEX
(operation → return-to-origin).
$EVROXWHUHVHWPRGHVFUHHQ
6WHS
4
Select "3" that corresponds to the
Z-axis.
use the cursor keys (
/
) to select an axis
number (Z-axis: 3) whose absolute reset is
performed.
Summary of Contents for R6YXG500
Page 1: ...ZX T Series Cat No I155E EN 03A R6Y XG series INSTALLATION MANUAL SCARA Robots XG Series...
Page 2: ......
Page 10: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 46: ......
Page 48: ......
Page 56: ......
Page 174: ......
Page 176: ......
Page 220: ......
Page 221: ...Chapter 4 Periodic inspection Contents 1 Overview 4 1 2 List of inspection items 4 2...
Page 222: ......
Page 226: ......
Page 227: ...Chapter 5 Harmonic drive replacement period Contents 1 Overview 5 1 2 Replacement period 5 2...
Page 228: ......
Page 232: ......
Page 238: ......
Page 240: ......
Page 244: ......
Page 246: ......
Page 323: ...8 Specifications 8 77 1 3 Robot inner wiring diagram Robot inner wiring diagram R6YXG500...