3
Robot settings
3-10
5
Select "M3" that corresponds to the
Z-axis.
Press the
(m3) key.
MANUAL
>RST.ABS 50%[MG][S0H0J]
Press F.key to get axis for ABSRST
M1= NG / Sensor M5= no axis
M2= NG / Sensor M6= no axis
M3= NG / TORQUE
M4= OK / Sensor
M1 M2 M3 M4 M5
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Z-axis
Absolute reset mode screen
Step 3-5
6
Perform the absolute reset.
The message "Reset AbS oK?" appears on the pb
screen.
7
Press the
(YES) key.
Check that there are no obstacles in the robot
movement range, and then press the
key
(YES).
To cancel the absolute reset, press the
(no)
key.
8
Check the machine reference value.
After the absolute reset has been completed, check
that the machine reference value displayed on the PB
is within the absolute reset tolerance range (25 to
75). (For R6YXGL250, R6YXGL350, R6YXGL400,
MANUAL
>RST.ABS>M3 50%[MG][S0H0J]
Starting origin search
Reset ABS OK?
YES NO
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Performing the absolute reset of the Z-axis
Step 6
R6YXGL500 and R6YXGL600, the recommended
range is between 30 and 70.)
MANUAL
>RST.ABS 50%[MG][S0H0J]
Machine reference (%)
M3= 49
M1 M2 M3 M4 M5
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
Machine reference value
Step 8
CAUTION
When adjusting the machine reference value, be sure to
check the adjustment machine reference value.
■
Machine reference value checking procedure
1. Press the
key.
2. Press the
key to enter the manual mode.
3. Press the
key (
+
) to select "RST.AbS".
4. After the Z-axis absolute reset is complete, press the
(
+
) key to display the adjustment machine
reference value (%).
If the machine reference value is outside the absolute reset tolerance range, then the next absolute reset may not be properly
performed. In this case, make the necessary adjustments while referring to
"2. Adjusting the origin" in this Chapter.
Summary of Contents for R6YXG500
Page 1: ...ZX T Series Cat No I155E EN 03A R6Y XG series INSTALLATION MANUAL SCARA Robots XG Series...
Page 2: ......
Page 10: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 46: ......
Page 48: ......
Page 56: ......
Page 174: ......
Page 176: ......
Page 220: ......
Page 221: ...Chapter 4 Periodic inspection Contents 1 Overview 4 1 2 List of inspection items 4 2...
Page 222: ......
Page 226: ......
Page 227: ...Chapter 5 Harmonic drive replacement period Contents 1 Overview 5 1 2 Replacement period 5 2...
Page 228: ......
Page 232: ......
Page 238: ......
Page 240: ......
Page 244: ......
Page 246: ......
Page 323: ...8 Specifications 8 77 1 3 Robot inner wiring diagram Robot inner wiring diagram R6YXG500...