34
External I/O Circuitry
Section 3-4
!Caution
Connect a load of 7 to 30 mA (or 7 to 16 mA for terminals with 1.6-k
Ω
limit
resistance) to the output section. If a current greater than this is used, it will
cause damage to the PCU’s internal components. Also, be sure to use the
CW/CCW output method when using pulse output terminals with limit resis-
tance.
Add bypass resistance for loads less than 7 mA.
Outputs (Line Driver Outputs on the CJ1W-NC133/NC233/NC433)
Note
Error counter reset output is open collector output.
!Caution
Connect a load of 20 mA max. to the output section. If a current greater than
this is used, it will cause damage to the PCU’s internal components.
Open collector output
Open collector output with 1.6 k
Ω
series resistance
Output
7 to 30 mA
Output transistor
Output
7 to 16 mA
24 VDC
power
supply
PCU
Driver
6 mA
1 mA
Bypass resistance
7 mA
(Circuit example)
Pulse output power supply, 5 VDC
Pulse output GND, 5 VDC
CW pulse output (+)
CW pulse output (–)
CCW pulse/direction output (+)
CCW pulse/direction output (–)
A4/B4
A3/B3
A5/B5
A6/B6
A7/B7
A8/B8
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...