333
Error Code Lists
Section 11-5
Interrupt feed-
ing
Interrupt feeding
position error
7200
The position designation of inter-
rupt feeding is outside the settable
range (–1,073,741,823 to
1,073,741,823 pulses).
Execute the com-
mand again after
correcting the posi-
tion or speed desig-
nation to a value in
the settable range.
The current START
command will not
be executed, but
other operating
axes will not be
affected.
Interrupt feeding
speed error
7201
The speed designation of interrupt
feeding is outside the settable
range (1 to 500,000 pps).
Interrupt feeding
acceleration time
error
7202
The acceleration time designation
of interrupt feeding is outside the
settable range (0 to 250 ms).
Interrupt feeding
deceleration time
error
7203
The deceleration time designation
of interrupt feeding is outside the
settable range (0 to 250 ms).
Origin return
Origin return
error
7300
The speed designation of origin
return is outside the settable range
(1 to 500,000 pps).
Origin return
acceleration time
error
7301
The acceleration time designation
of origin return is outside the setta-
ble range (0 to 250 s).
Origin return
deceleration time
error
7302
The deceleration time designation
of origin return is outside the setta-
ble range (0 to 250 s).
Present posi-
tion
Present position
error
7400
The position designated with
present position preset is outside
the settable range
(–1,073,741,823 to
1,073,741,823).
JOG
JOG speed error 7500
The JOG speed is outside the set-
table range (1 to 500,000 pps).
JOG accelera-
tion time error
7501
The JOG acceleration time is out-
side the settable range (0 to
250 s).
JOG decelera-
tion time error
7502
The JOG deceleration time is out-
side the settable range (0 to
250 s).
Group
Name
Code
Cause
Clearing method
Operation after
error
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...