190
Acceleration/Deceleration
Section 7-6
Next Command
• Position
• Speed, V
2
(pps)
Note
When the designations for the next positioning operation are given during
operation, T
2
and T
3
are calculated using the acceleration time Ta and decel-
eration time Td specified at the time operation started from the stopped posi-
tion. It is not necessary to specify new acceleration and deceleration times.
Case 2: Speed for the Next Positioning Operation is Slower
In this case (V
1
>
V
2
), the calculations will be the same as before except for T
2
,
which is determined according to the following equation.
Actual acceleration time T
2
= (V
1
– V
2
)/(V
MAX
– V
0
)
×
Td
7-6-3
Calculating Accel/Decel Times for Speed Changes during
Operation
If the speed or the override setting is changed during direct operation, the
motor will be accelerated or decelerated to the new speed. The actual accel-
eration and deceleration times for this kind of operation can be calculated in
the way shown below.
Case 1: Next Speed is Faster
Actual acceleration time, T
1
= (V
1
– V
0
)/(V
MAX
– V
0
)
×
Ta
Actual acceleration time, T
2
= (V
2
– V
1
)/(V
MAX
– V
0
)
×
Ta
Actual deceleration time, T
3
= (V
2
– V
0
)/(V
MAX
– V
0
)
×
Td
• The following axis parameter settings are used:
• Maximum speed, V
MAX
(pps)
• Initial speed, V
0
(pps)
Speed
Speed V
2
Speed V
1
Initial speed V
0
Actual
acceleration
time T
1
Actual
acceleration
time T
2
Actual
deceleration
time T
3
Time
First positioning operation
Next positioning operation
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...