279
Memory Operation
Section 10-2
Program
W030 is used as a work word.
10-2-3 Cancelling Positioning
Overview
• A forced interrupt can be used during memory operation to cancel the
current positioning and perform a circumvention in case of an emergency.
• This operation forcibly cancels the current positioning operation and exe-
cutes positioning from the designated sequence number.
• The pulses currently being output are stopped immediately without decel-
eration.
Operation start
switch
Busy Flag
Sets #0 for the
sequence number.
Sequence
Number Enable
Enables the
sequence number.
START
No Origin
Flag
Takes the rising edge of the
operation start switch.
Only executed when
starting the first
time.
Executed when
starting from the
second time
onwards.
No Origin Flag
Busy Flag
W03000
200206
200213
W03001
D00516
DIFU
W03000
200000
W03014
W03015
W03001
W03000
200206
200213
W03001
W03014
W03015
W03001
200001
200001
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...