278
Memory Operation
Section 10-2
Speeds
Note
Addresses other than the above should be set to their default settings (0).
Positions
Note
Addresses other than the above should be set to their default settings (0).
Acceleration and
Deceleration Times
Note
Addresses other than the above should be set to their default settings (0).
Dwell Times
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Address
Setting
Contents of setting
112C
0096
Speed #0
150 pps (96 Hex)
112D
0000
112E
012C
Speed #1
300 pps (12C Hex)
112F
0000
1130
0190
Speed #2
400 pps (190 Hex)
1131
0000
1132
01F4
Speed #3
500 pps (1F4 Hex)
1133
0000
1134
0000
Speed #4
0 pps (0 Hex)
1135
0000
Address
Setting
Contents of settings
11F4
03E8
Position #0
1,000 pulses (3E8 Hex)
11F5
0000
11F6
08CA
Position #1
2,250 pulses (8CA Hex)
11F7
0000
11F8
0CB2
Position #2
3,250 pulses (CB2 Hex)
11F9
0000
11FA
1194
Position #3
4,500 pulses (1194 Hex)
11FB
0000
11FC
03E8
Position #4
1,000 pulses (3E8 Hex)
11FD
0000
11FE
0000
Position #5
0 pulses (0 Hex)
11FF
0000
Address
Setting
Contents of settings
12BE
0005
Acceleration time #1
5 ms (5 Hex)
12BF
0000
12C0
0014
Acceleration time #2
20 ms (14 Hex)
12C1
0000
12D2
0005
Deceleration time #1
5 ms (5 Hex)
12D3
0000
12D4
0014
Deceleration time #2
20 ms (14 Hex)
12D5
0000
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...