247
Deceleration Stop
Section 9-5
If the completion code is continuous, positioning returns to the target position
of sequence #0 and an immediate reversal is executed without deceleration.
Then positioning is executed for sequence #1.
Deceleration Stop During
Positioning with Relative
Positions
When positioning is stopped by a deceleration stop, the sequence that was
stopped is re-executed by starting positioning again.
Deceleration Stop with
Linear Interpolation
A deceleration stop with linear interpolation is executed by the STOP Bit of the
axis for which the START Bit (to start memory operation) is turned ON. After
deceleration has been completed, the Deceleration Stop Execution Flag is
turned ON. The STOP Bits of other axes are disabled.
For example, when executing linear interpolation for X-axis data with the X
and Y axes, deceleration stop can only be executed by the Deceleration Stop
Bit of the X axis. When deceleration stop is executed during interpolation
operation, both the X and Y axes stop from deceleration.
When positioning is restarted, the target position will vary, as shown below,
according to whether the positions for each active axis are relative or abso-
lute. In this example, linear interpolation is executed for the X and Y axes.
When X Axis Position is Relative and Y Axis is Absolute
When positioning is stopped by a deceleration stop, the sequence that was
stopped can be re-executed by restarting X-axis positioning. Positioning will
be resumed for the Y axis.
START
STOP
Pulse
output
Speed
Sequence
#0
Time
Past target position
Sequence
#1
Immediate reversal.
Sequence #0
#0
START
STOP
Pulse
output
Speed
Sequence
#0
Time
Sequence
#0
Sequence
#1
Y axis
X axis
Target position
Completion of start
Re-start
STOP
Interpolation start
begins
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...