282
Memory Operation
Section 10-2
Positioning Sequences
Note
Addresses other than the above should be set to their default settings (0).
Address
Setting
Contents of setting
1000
1000
Sequence #0 X axis designation
Output code: 0
Position designation: absolute
Completion code: terminating
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #1
1001
0011
1002
0401
1003
1012
Sequence #1 X axis designation
Output code: 0
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #3
1004
0022
1005
0403
1006
1012
Sequence #2 X axis designation
Output code: 0
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #1
1007
0022
1008
0401
1009
1013
Sequence #3 X axis designation
Output code: 0
Position designation: relative
Completion code: bank end
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #2
100A
0022
100B
0402
100C
1002
Sequence #4 X axis designation
Output code: 0
Position designation: absolute
Completion code: continuous
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #3
100D
0011
100E
0403
100F
1003
Sequence #5 X axis designation
Output code: 0
Position designation: absolute
Completion code: bank end
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #0
1010
0011
1011
0400
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...