172
Origin Search Timing Charts
Section 6-5
6-5-3
Origin Search Deceleration Stop
When a deceleration stop is executed during an origin search, the origin
search is canceled. The following diagram shows an example of a decelera-
tion stop during an origin search when there is an origin proximity input signal
reversal.
Pulse output
Time
Origin proximity
input signal
Origin input
signal
ORIGIN
SEARCH
Start
Stop
Positioning
Completed
Flag
Busy Flag
Limit signal input
(in search
direction)
STOP
Start
Deceleration
Stop Execution
Flag
No Origin Flag
Origin Stop Flag
Error counter
reset output