341
Error Display at the CPU
Section 11-7
11-7 Error Display at the CPU
The CPU Unit monitors the PCU, which is a Special I/O Unit, for the following
items.
• Hardware irregularities
• Unit number settings outside the settable range
• Duplicated unit numbers
• I/O refresh between the CPU Unit and the PCU
If an error is detected for one of the above items, one of the following flags in
the Auxiliary Area will turn ON. (For details, refer to the relevant CPU Unit
operation manual.)
• Special I/O Unit Number Duplication Flag
• Special I/O Unit Setting Error Flag
• Special I/O Unit Setting Error, Unit Number Flag
• Special I/O Unit Error Flag
• Special I/O Unit Error, Unit Number Flag
For methods of clearing errors, refer to
11-3 LED Error Indicators
and
11-5
Error Code Lists
. After the error has been cleared, the PCU can be restarted
without resetting the power supply by using (OFF
→
ON
→
OFF) one of the fol-
lowing restart bits.
Restart Bits
11-8 Reading Error Information with CX-Position
The following two types of error information can be displayed at the CX-Posi-
tion.
• The current error
• The errors that occurred since the power was turned ON or the PCU was
restarted, including the present error (20 max.)
For details, refer to the CX-Position Operation Manual (W433).
Bit address
Function
A50200 to A50215
Restart bits for unit numbers 0 to 15
A50300 to A50315
Restart bits for unit numbers 16 to 31
A50400 to A50415
Restart bits for unit numbers 32 to 47
A50500 to A50515
Restart bits for unit numbers 48 to 63
A50600 to A50615
Restart bits for unit numbers 64 to 79
A50700 to A50715
Restart bits for unit numbers 80 to 95
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...