![background image](http://html1.mh-extra.com/html/omron/cj1w-c113-rev-02-2008/cj1w-c113-rev-02-2008_operation-manual_742339046.webp)
19
Basic Procedures
Section 2
Note
1.
Perform wiring according to instructions given in the motor and motor driv-
er’s operation manuals.
2.
Refer to the operation manual for the CPU Unit.
3.
Use the axis parameter designation setting in the common parameter area
to specify whether for operation is performed according to axis parameters
saved in the PCU or the axis parameters set in the CPU Unit’s DM Area.
Flow of operation
Reference
Programming
and test oper-
ation
SECTION 6 Defining the Origin
SECTION 7 Direct Operation
SECTION 8 Memory Operation
SECTION 9 Other Operations
Debugging
SECTION 11 Troubleshooting
Operation
SECTION 10 Program Exam-
ples
Maintenance
SECTION 12 Maintenance and
Inspection
!
(Continued from previous page.)
Establish the origin of the motor axis
for operation.
Directly set the target position and speed
from the CPU Unit and start the motor.
Record a positioning sequence (including
positions and speeds) and operate the
motor in accordance with this sequence.
Is there an error?
Execute other PCU functions, such as
jogging or teaching.
Start PLC (and PCU) operation.
Perform regular inspections.
Yes
No
Check the LED indicators on the
front of the PCU.
Read the PCU's error code.
Remove the cause of the error
and clear the error status.
END
Read the sequence data saved in the PCU.
Write the sequence data to the PCU.
Save the written sequence data in the PCU.
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...