Completion Codes
Section 8-5
To stop speed control, execute the STOP command.
Interrupt Feeding
Completion
(Codes 5 and 6)
With interrupt feeding completion, pulse output is supported at the target
speed in this positioning sequence. The present position can be calculated
even during continuous output. The direction of the pulse output is set by the
sign for the position data of the same number. When an interrupt signal is
input, positioning is carried out according to the position data that is set. The
positioning direction depends on the completion code. The next sequence
Speed
Sequence
#n
Time
Sequence
number
Sequence
Number Enable
START or
INDEPENDENT
START
STOP
CPU Unit to PCU