24
Installation
Section 3-3
2.
Be sure to set the unit numbers so that they do not overlap with the unit
numbers of other Special I/O Units.
3.
Since the CJ1W-NC413/433 are allocated the words for two unit numbers,
unit number 95 cannot be set.
3-3
Installation
3-3-1
System Configuration Considerations
• The additional functions supported by Unit version 2.0 can be used only if
the PCU is installed with a CJ1-H or CJ1M CPU Unit (either CPU Unit Ver.
2.0 or Pre-Ver. 2.0 CPU Unit). These functions cannot be used by PCUs
installed with CJ1 CPU Units.
For details on Unit versions, refer to
Unit Versions of CJ-series Position
Control Units
on page vi. For details on additional functions supported for
Unit version 2.0, refer to
Unit Versions of CJ-series Position Control Units
on page vi.
• The I/O bits allocated to a particular Special I/O Unit are determined by
the unit number that is set by the switch on the front panel of the Unit, and
not by the position in which the Unit is mounted.
• The PCU can be connected to CPU Racks or Expansion Racks (up to 10
PCUs per Rack). Up to 40 PCUs can be connected per CPU Unit.
3-3-2
Mounting the Unit
Follow the procedure outlined below to mount the Position Control Unit.
1,2,3...
1.
Join the PCU to the Rack, ensuring that the connectors engage properly.
2.
Secure the PCU by sliding the yellow sliders on the top and bottom until
they click into place.
Note
If the sliders are not locked into place properly, the PCU may not be able to
maintain full functionality.
PA205R
POWER
INPUT
AC100-240V
L2/N
L1
DC24V
AC240V
OUTPUT
RUN
PERIPHERAL
ERR/ALM
RUN
INH
COMM
PRPHL
CONTROLLER
CJ1G-CPU44
SYSMAC
PROGRAMMABLE
PORT
OPEN
BUSY
MCPWR
NC413
0
12
34
5
6
789
0
12
34
5
6
789
RUN
ERC
ERH
Z
U
X
Y
MACH
No.
10
1
10
0
20
1
1
20
U Z
C
N
1
C
N
2
Connector
PA205R
POWER
INPUT
AC100-240V
L2/N
L1
DC24V
AC240V
OUTPUT
RUN
PERIPHERAL
ERR/ALM
RUN
INH
COMM
PRPHL
CONTROLLER
CJ1G-CPU44
SYSMAC
PROGRAMMABLE
PORT
OPEN
BUSY
MCPWR
NC413
0
12
34
5
6
789
0
12
34
5
6
789
RUN
ERC
ERH
Z
U
X
Y
MACH
No.
10
1
10
0
20
1
20
C
N
1
C
N
2
Slider
Lock
Release
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...