161
Origin Search Operation
Section 6-4
Origin Detection Method: 3
Deceleration starts on the rising edge of the limit input signal. After the signal
turns OFF, an origin adjustment command output turns ON. If the deceleration
is insufficient while the limit input signal is ON, there will be an error.
Pulse output
Time
Time
Pulse output
Origin adjustment
command output
Z-phase signal
Origin proximity
input signal
Origin adjustment
command output
Start
Stop
Stop
Start
When
deceleration
time is long
When
deceleration
time is short
Pulse
output
Time
Origin
adjustment
command
output
Start
Limit input
signal
Positioning
completed
input signal
Busy Flag
Stop