245
Deceleration Stop
Section 9-5
The commands that cannot be used when the STOP Bit is ON are shown in
the following table.
9-5-2
Beginning Words of Memory Areas
The beginning words of the operating memory area, operating data area, and
common parameter area used for a Position Control Unit (PCU) are deter-
mined (or set) according to the following.
• Beginning word of the operating memory area, n = CIO 2000 + 10
×
unit
number
• Beginning word of the common parameter area, m = 100
×
unit
number
• Beginning word of the operating data area, l, is specified in m and m+1.
Command
Executable while
STOP Bit is ON
Memory operation
START
No
INDEPENDENT START
No
FORCED INTERRUPT
No
Direct operation
ABSOLUTE MOVEMENT
No
RELATIVE MOVEMENT
No
INTERRUPT FEEDING
No
Other
ORIGIN SEARCH
No
ORIGIN RETURN
No
PRESENT POSITION PRESET
Yes
JOG
No
TEACH
Yes
RELEASE PROHIBIT/ERROR RESET
Yes
Error counter reset output, origin
adjustment command output
Yes
Override enable
Yes
Data transfer
WRITE DATA
Yes
READ DATA
Yes
SAVE DATA
Yes
There is no pulse output when JOG is executed.
Also, there is no change to the status of the Busy
Flag and the Deceleration Stop Execution Flag while
in this state (i.e., the STOP Bit and JOG are ON).
STOP
JOG
Pulse output
Deceleration Stop
Execution Flag
CPU
PCU
CPU
PCU
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...