59
Connection Examples for Different Types of Motor Driver
Section 3-6
SMARTSTEP A-series Servo Drive (CJ1W-NC113/NC213/NC413)
R7M-A
@
Servomotor
Position Control
Unit (open collector outputs
on the CJ1W-NC
@
13)
Example:
OMRON R7D-AP
@@@
Shield
A6
A8
A1
A2
2
4
1
3
−
CW
−
CCW
+CW
+CCW
6
33
5
32
−
ECRST
ZCOM
FG
+ECRST
RUN
+24VIN
Z
13
14
A10
A13
A12
A11
INP
8
0GND
10
FG
24-V power
supply for
output
24-V GND
for output
Origin input
signal
CCW output
(with 1.6-k
Ω
resistance)
Error counter
reset output
CW output
(with 1.6-k
Ω
resistance)
Positioning
completed
input signal
+
24 VDC
N.O.
contact
Shell
Servo Drive
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...