58
Connection Examples for Different Types of Motor Driver
Section 3-6
Parameter Setting Example
This example is explained in terms of the X axis. For more details, refer to
4-4
Axis Parameter Area
.
Note
“m” is the beginning DM word allocated when the unit number is set.
Origin Search Operation
The origin search operation stops on the rising edge of the first Z-phase sig-
nal after the origin proximity signal has turned from ON to OFF, and after
deceleration has ended. The Busy Flag turns OFF with the positioning com-
pleted input signal.
Word
Bits
Setting
Contents
m+4
00
0
CW/CCW output
01 to 03
0
---
04
0
Limit input: N.C. contact
05
1
Origin proximity: N.O. contact
06
1
Origin input signal: N.O. contact
07
1
Pulse output stopped by emergency
stop input signal; error counter reset
signal output.
08 to 15
0
---
m+5
00 to 03
2
Mode 2
04 to 07
0
Reverse mode 1
08 to 11
0
Takes origin input signal after rising
and falling edge of origin proximity
input signal.
12 to 15
0
Search direction: CW
0
0
E
0
m+4
0
0
0
2
m+5
15
0
ORIGIN
SEARCH
Origin proximity
signal
Z phase signal
Pulse output
Busy Flag
Time
Error counter
reset output
Approx. 20 ms
Positioning completed
input signal
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...