108
Examples of Parameter Settings
Section 4-9
Note
Operation will be performed for PCUs with unit version 2.0 or earlier. The
emergency stop for the Y axis, however, requires wiring. Some parameter set-
tings will also vary.
Parameter Settings
• Set the default settings using the CX-Programmer.
• Make the following settings for the X axis.
• With the following settings, jog operation and direct operation can be per-
formed from the CPU Unit.
• When performing an origin search, make the settings and adjustments
according to each system.
m = 100 x unit number
= 100 x 0 = D20000
Default Settings and Set Values: Parameters for which individual bits have
specific applications are expressed in hexadecimal (e.g., 0000H).
Category
Word
Name
Default setting
Set value
Remarks
Common
Parameters
m
Operating data area des-
ignation
---
0000H
The operating data area
is allocated between to
m+60 and m+99.
m + 1
Beginning word of oper-
ating data area
---
0000H
m + 2
Axis parameter designa-
tion
---
1001H
Only the X axis is used.
The operating data area
is allocated between
m+4 and m+59.
m + 3
Not used.
---
0000H
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...