Page 1: ...Multisystem solar controller With support for additional devices two collectors areas for central and water heating IB Tron 4000 SOL ...

Page 2: ... Fresh water circulation pump_________ 10 Bacteriological protection____________ 11 Hysteresis_________________________ 11 Extra heating busters________________ 11 Frost protection____________________ 13 High temperature protection_________ 13 Choice of tank______________________ 14 Loading pumps____________________ 14 P0 and P1 pump speed______________ 15 SMART START______________________ 17 GUAR...

Page 3: ...ction in two modes de pends of user setting Winter heating building only Fresh water tank is not heated at all by so lar and other heating busters Summer cooling tanks and extra heating busters not working at all e e Bacteriological protection of fresh wa ter tank e e GUARD function protection devices from damage e e Reloading heat between tanks e e SMART START function controller in telligently c...

Page 4: ...T1 T3 T6 T5 T2 H1 T4 T0 1 P System 2 H2 P0 P2 P3 R1 P1 e e The appearance of display depending of chosen system of work Some items may not be visible e e Flashing pump symbol means that this pump works at the moment If the sym bol is not flashing means that pump does not work now I IWith controller are provided follow sensors 2x PT1000 Sensors connected to T0 and T1 5x NTC10kOhm Sensors connected ...

Page 5: ...0 1 057 20 1 097 30 1 136 40 1 175 50 1 215 60 1 254 70 1 292 80 1 331 90 1 370 100 1 408 110 1 447 120 1 485 130 1 523 140 1 561 150 1 599 160 1 597 170 1 645 180 1 712 190 1 750 200 1 787 210 1 774 220 1 810 230 1 847 240 1 875 250 1 912 260 2 008 270 2 045 280 2 081 Calibration After properly connecting controller is ready to work Controller is factory calibrated to work with standard sensors H...

Page 6: ...king simultaneously In fact the second collectors area may be re spectively hydraulically connected another device which produces thermal energy for example heating fireplace when temperature difference of the second collectors area T0 and temperature in the tank T2 reaches the set value of switching on Circulation pumps P1 and P0 are wor king independently from each other the pumps may work simul...

Page 7: ...r circula tion pump is turned on parameter adjustment available only for first method of control T4off Hysteresis between turning on and turning off fresh water cir culation pump parameter adju stment only for first method of control on Work time period min how long the pump has to work in one cycle parameter adjustment ava ilable only for second method of control After selecting control method yo...

Page 8: ...nal linear weather compensator Such controllers are available in our offer Fresh water circulation pump Bacteriological protection Bacteriological protection Extra heating busters off Break time period min ever this time period circulation pump will be turned on parameter ad justment available only for second method of control P1 on Beginning of first period of work P1 off End of first period of w...

Page 9: ...lease do not confuse energy with temperature To adjust parameters of this function please Press and hold button Repeatedly press the button to set further parameters 1 OptimalT2temperature for first method of choice 2 Method of tank choice by former description Set desired value of the parameter Confirm set data OK AH AH High temperature protection High temperature protection Frost protection Cont...

Page 10: ...t data OK Loading pumps Loading pumps Solar system for whole day heat both tanks completely 1 and 2 First tank is fresh water tank At evening residents of building cool first tank hey used hot water Normally at this point extra heating buster should be turned on to heat fresh water tank such as electric heater extra heating buster feature has been previously described in this manu al However when ...

Page 11: ...erefore in fact often happens that collec tor could start work earlier few minutes than this happened in practice While in days with high solar radiation this energy losses arising from this delay is negligible but in winter days with lower solar radiation there is quite a lot of this energy losses To solve this problem and increase energy output IB Tron 4000SOL controller is equip ped with a spec...

Page 12: ... function setting Tmax Temperature units Press and hold two buttons simultaneously Tmin Tmax Software version Press and hold two buttons simultaneously Tmax OK T Test functions In addition there is possible to test logic of system work by sensor test function When this function is on sensors no longer making real measurement user are able to simulate absolute values from controller keyboard contro...

Page 13: ...e Warranty fore its purchase sale at distance it is possible to return goods within 10 days Returned goods cannot bear signs of exploitation itmustcontainallelements with which it was delivered e e In the case of return of purchased go ods all shipping costs are on buyer side Before return of goods please contact with seller e e Terms of warranty may be changed by local InsBud company partner Shor...

Page 14: ...ul Niepodlegości 16a 32 300 Olkusz POLAND tel fax 48 32 643 26 87 e mail insbud insbud net ...