Repeatedly press the button to set 

further parameters:

T3 on

 - 

T3

 comfortable tempera-

ture - up to this temperature first 

tank is heated by 

H1

T3off

 - Hysteresis for 

H1

 - applica-

ble for 

T3

T3 P1 on

 - First period of 

H1

: be-

ginning of period

T3 P1 off

 - First period of 

H1

: end 

of period

T3 P2 on

 - Second period of 

H1

beginning of period

T3 P2 off

 - Second period of 

H1

end of period

T6 on

 - 

T6

 comfortable temperatu-

re - up to this temperature second 

tank is heated by 

H2

 (only for sys-

tems with two tanks)

T6 off

 - Hysteresis for 

H2

 - appli-

cable for 

T6 

(only for systems with 

two tanks)

T6 P1 on

 - First period of 

H2

: be-

ginning of period (only for systems 

with two tanks)

T6 P1 off

 - First period of 

H2

: end 

of period (only for systems with 

two tanks)

T6 P2 on

 - Second period of 

H2

beginning of period (only for sys-

tems with two tanks)

T6 P2 off

 - Second period of 

H2

end of period (only for systems 

with two tanks)

E

xTRa

 

hEaTing

 

BusTERs

E

xTRa

 

hEaTing

 

BusTERs

water in tanks (directly or by exchange coil), 

etc.

Please note that the maximum load of 

H1

 

and 

H2

 can not exceed values given in tech-

nical data of this manual. For bigger loads of 

extra heating busters please use additional 

external relays of adequate power.

Controller is designed for extra heating bu-

sters located in upper parts of tanks so that it 

does not heat whole tank just top part of it.

If temperature in upper part of first tank (

T3

)  

drops below comfortable set value (for spe-

cific period of time) 

H1

 device will be turned 

on until it reach desired comfortable tempe-

rature (including hysteresis value).

Similarly 

H2

 deviece is turned on when tem-

perature in upper part of second tank (

T6

drops below comfortable set value.

For each tank can be set two independent 

periods of time (for a day) in which extra he-

ating busters are controlled (outside this pe-

riods extra heating busters are never turned 

on).

To adjust parameters of the function please:

AH

Set desired value of the parameter.

Confirm set data.

OK

 

I

In some heating systems, it is desirable 

that temperature at top of buffer tank 

(tank 2) was variable and dependent 

on outside temperature (colder outside 

- higher required temperature 

T6

, war-

mer  outside - lower required tempera-

ture 

T6

). This effect can be achieved by 

additional linear weather compensator. 

Such controllers are available in our 

offer.

f

REsh

 

WaTER

 

ciRculaTiOn

 

pump

B

acTERiOlOgical

 

pROTEcTiOn

B

acTERiOlOgical

 

pROTEcTiOn

E

xTRa

 

hEaTing

 

BusTERs

off

 - Break time period [min] - ever 

this time period circulation pump 

will be turned on (parameter ad-

justment available only for second 

method of control)

P1 on

 - Beginning of first period of 

work

P1 off

 - End of first period of work

P2 on

 - Beginning of second pe-

riod of work

P2 off

 - End of second period of 

work
Set desired value of the parameter.

select temperature protection va-

lue (recommended  value is 70 ºC) 

or turn 

OFF

 protection function.

Confirm set data.

OK

Caring for health of user, the controller is 

equipped with bacteriological protection of 

fresh water tank, this feature prevents the 

tank before legionell bacteria (legionnaires).

Optimal temperature for growth of the Le-

gionella pneumophila bacteria in the labo-

ratory is 37ºC. At higher temperatures these 

micro-organisms proliferation decreases, at 

46ºC it stops. Bacteria can survive at higher 

temperatures, but decreases survival time of 

several hours at  50ºC and of few minutes at 

60ºC. At 70ºC bacteria is killed instantly.

Controller controls maximum temperature 

which was in fresh water tank within 7 days. If 

at that time temperature in fresh water tank 

remained at low level there is a risk of bacte-

ria appearance. Therefore, if such a situation 

occurs (temperature in fresh water tank for 7 

days, will not increase above the set protect 

value), controller is turning on an additional 

source of heat (extra heating buster) 

H1

 and 

remains turned on until protection tempera-

ture will be achieved. 

Bacteriological protection function is recom-

mended in all cases, but you can disable it if 

necessary.

To enable / disable bacteriological protection 

function please:

Controller is equipped with additional, inde-

pendent, strong relays 

H1

 and 

H2

, into which 

you can connect an additional source of heat 

(extra heating busters). This source of heat 

may be e.g. electric heater, gas boiler heating 

Press and hold button.

Confirm set data.

OK

h

ysTEREsis

Controller allows full adjustment of hystere-

sis for multiple functions.

Hysteresis is delay between turning on/off of 

device Higher value of hysteresis means less 

cycles of controlled device (e.g. pumps) and 

thus increases the vitality of the device.

In normal conditions it is recommended to 

set hysteresis value to 2 ºC (for liquid).  Value 

setting of hysteresis depends on where the 

measurement is.

Summary of Contents for IB-TRON 4000 SOL

Page 1: ...Multisystem solar controller With support for additional devices two collectors areas for central and water heating IB Tron 4000 SOL ...

Page 2: ... Fresh water circulation pump_________ 10 Bacteriological protection____________ 11 Hysteresis_________________________ 11 Extra heating busters________________ 11 Frost protection____________________ 13 High temperature protection_________ 13 Choice of tank______________________ 14 Loading pumps____________________ 14 P0 and P1 pump speed______________ 15 SMART START______________________ 17 GUAR...

Page 3: ...ction in two modes de pends of user setting Winter heating building only Fresh water tank is not heated at all by so lar and other heating busters Summer cooling tanks and extra heating busters not working at all e e Bacteriological protection of fresh wa ter tank e e GUARD function protection devices from damage e e Reloading heat between tanks e e SMART START function controller in telligently c...

Page 4: ...T1 T3 T6 T5 T2 H1 T4 T0 1 P System 2 H2 P0 P2 P3 R1 P1 e e The appearance of display depending of chosen system of work Some items may not be visible e e Flashing pump symbol means that this pump works at the moment If the sym bol is not flashing means that pump does not work now I IWith controller are provided follow sensors 2x PT1000 Sensors connected to T0 and T1 5x NTC10kOhm Sensors connected ...

Page 5: ...0 1 057 20 1 097 30 1 136 40 1 175 50 1 215 60 1 254 70 1 292 80 1 331 90 1 370 100 1 408 110 1 447 120 1 485 130 1 523 140 1 561 150 1 599 160 1 597 170 1 645 180 1 712 190 1 750 200 1 787 210 1 774 220 1 810 230 1 847 240 1 875 250 1 912 260 2 008 270 2 045 280 2 081 Calibration After properly connecting controller is ready to work Controller is factory calibrated to work with standard sensors H...

Page 6: ...king simultaneously In fact the second collectors area may be re spectively hydraulically connected another device which produces thermal energy for example heating fireplace when temperature difference of the second collectors area T0 and temperature in the tank T2 reaches the set value of switching on Circulation pumps P1 and P0 are wor king independently from each other the pumps may work simul...

Page 7: ...r circula tion pump is turned on parameter adjustment available only for first method of control T4off Hysteresis between turning on and turning off fresh water cir culation pump parameter adju stment only for first method of control on Work time period min how long the pump has to work in one cycle parameter adjustment ava ilable only for second method of control After selecting control method yo...

Page 8: ...nal linear weather compensator Such controllers are available in our offer Fresh water circulation pump Bacteriological protection Bacteriological protection Extra heating busters off Break time period min ever this time period circulation pump will be turned on parameter ad justment available only for second method of control P1 on Beginning of first period of work P1 off End of first period of w...

Page 9: ...lease do not confuse energy with temperature To adjust parameters of this function please Press and hold button Repeatedly press the button to set further parameters 1 OptimalT2temperature for first method of choice 2 Method of tank choice by former description Set desired value of the parameter Confirm set data OK AH AH High temperature protection High temperature protection Frost protection Cont...

Page 10: ...t data OK Loading pumps Loading pumps Solar system for whole day heat both tanks completely 1 and 2 First tank is fresh water tank At evening residents of building cool first tank hey used hot water Normally at this point extra heating buster should be turned on to heat fresh water tank such as electric heater extra heating buster feature has been previously described in this manu al However when ...

Page 11: ...erefore in fact often happens that collec tor could start work earlier few minutes than this happened in practice While in days with high solar radiation this energy losses arising from this delay is negligible but in winter days with lower solar radiation there is quite a lot of this energy losses To solve this problem and increase energy output IB Tron 4000SOL controller is equip ped with a spec...

Page 12: ... function setting Tmax Temperature units Press and hold two buttons simultaneously Tmin Tmax Software version Press and hold two buttons simultaneously Tmax OK T Test functions In addition there is possible to test logic of system work by sensor test function When this function is on sensors no longer making real measurement user are able to simulate absolute values from controller keyboard contro...

Page 13: ...e Warranty fore its purchase sale at distance it is possible to return goods within 10 days Returned goods cannot bear signs of exploitation itmustcontainallelements with which it was delivered e e In the case of return of purchased go ods all shipping costs are on buyer side Before return of goods please contact with seller e e Terms of warranty may be changed by local InsBud company partner Shor...

Page 14: ...ul Niepodlegości 16a 32 300 Olkusz POLAND tel fax 48 32 643 26 87 e mail insbud insbud net ...

Reviews: