69
Data Areas
Section 4-2
Operating Memory Area (refer to page 95)
Beginning word of operating memory area, n = 2000 + 10
×
unit number.
Words
Bits
Operation
1 axis
2 axes
4 axes
X axis X axis Y axis X axis Y axis Z axis U axis
n
n
n+2
n
n+2
n+4
n+6
00
Sequence Number Enable
01
START
02
INDEPENDENT START
03
ABSOLUTE MOVEMENT
04
RELATIVE MOVEMENT
05
INTERRUPT FEEDING
06
ORIGIN SEARCH
07
ORIGIN RETURN
08
PRESENT POSITION PRESET
09
JOG
10
Direction designation
11
TEACH
12
RELEASE PROHIBIT/ERROR RESET
13
Error counter reset output/origin-adjustment command
output
14
Override Enable
15
STOP
n+1
n+1
n+3
n+1
n+3
n+5
n+7
00 to
07
Not used
08
FORCED INTERRUPT
09 to
11
Not used
12
WRITE DATA
13
READ DATA
14
SAVE DATA
15
Not used
n+2
n+4
n+7
n+8
n+11
n+14
n+17
00 to
03
Not used
04
Waiting For Memory Operation Flag
05
Positioning Completed Flag
06
No Origin Flag
07
Origin Stop Flag
08
Zone 0 Monitor Flag
09
Zone 1 Monitor Flag
10
Zone 2 Monitor Flag
11
Teaching Completed Flag
12
Error Flag
13
Busy Flag
14
Data Transferring Flag
15
Deceleration Stop Execution Flag
Summary of Contents for CJ1W-C113 - REV 02-2008
Page 2: ...CJ1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 27: ...xxviii Conformance to EC Directives 6 ...
Page 43: ...16 Control System Principles Section 1 7 ...
Page 47: ...20 Basic Procedures Section 2 ...
Page 139: ...112 Examples of Parameter Settings Section 4 9 ...
Page 173: ...146 Transferring Data with CX Position Section 5 7 ...
Page 223: ...196 Sample Program Section 7 7 ...
Page 259: ...232 Sample Program Section 8 10 ...
Page 293: ...266 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 369: ...342 Reading Error Information with CX Position Section 11 8 ...
Page 385: ...358 Common Parameter Area Appendix C ...