switchport
vlan-stack trunk
no shutdown
Dell(conf-if-te-1/1/2/1)# interface vlan 100
Dell(conf-if-vl-100)# vlan-stack compatible
Dell(conf-if-vl-100-stack)# member tengigabitethernet 1/1/2/1
Dell(conf-if-vl-100-stack)# show config
!
interface Vlan 100
no ip address
vlan-stack compatible
member TenGigabitEthernet 1/1/2/1
shutdown
Dell(conf-if-vl-100-stack)# interface vlan 20
Dell(conf-if-vl-20)# tagged Tengigabitethernet 1/1/2/1
Dell(conf-if-vl-20)# show config
!
interface Vlan 20
no ip address
tagged TenGigabitEthernet 1/1/2/1
shutdown
Dell(conf-if-vl-20)# do show vlan
Codes: * - Default VLAN, G - GVRP VLANs
Q: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Vlan-stack
NUM Status Description Q Ports
* 1 Inactive
20 Active T Te 1/1/2/1
100 Active M Te 1/1/2/1
Dell(conf-if-vl-20)#
Example 2
Dell(config)# vlan-stack protocol-type 88A8
Dell(config)# interface TenGigabitethernet 1/1/2/1
Dell(conf-if-te-1/1/2/1)# no shutdown
Dell(conf-if-te-1/1/2/1)# switchport
Dell(conf-if-te-1/1/2/1)# vlan-stack access
Dell(conf-if-te-1/1/2/1)# exit
Dell(config)# interface TenGigabitethernet 1/1/3/1
Dell(conf-if-te-1/1/3/1)# no shutdown
Dell(conf-if-te-1/1/3/1)# portmode hybrid
Dell(conf-if-te-1/1/3/1)# switchport
Dell(conf-if-te-1/1/3/1)# vlan-stack trunk
Dell(conf-if-te-1/1/3/1)# exit
Dell(config)# interface vlan 10
Dell(conf-if-vlan)# vlan-stack compatible
Dell(conf-if-vlan)# member Te 1/1/4/1, Te 1/1/4/2, TenGi 1/1/4/3
Dell(conf-if-vlan)# exit
Dell(config)# interface vlan 30
Dell(conf-if-vlan)# untagged TenGi 1/1/4/2
Dell(conf-if-vlan)# exit
Dell(config)#
Dell(config)# interface vlan 40
Dell(conf-if-vlan)# tagged TenGi 1/1/4/2
Dell(conf-if-vlan)# exit
Dell(config)#
1648
VLAN Stacking
Содержание S6100
Страница 1: ...Dell Command Line Reference Guide for the S6100 ON System 9 11 2 0P1 ...
Страница 474: ...protocol list ttl0 ttl1 Dell 474 Control Plane Policing CoPP ...
Страница 979: ... show lldp neighbors display the LLDP neighbors Link Layer Discovery Protocol LLDP 979 ...
Страница 1627: ... uplink state group creates an uplink state group and enables the tracking of upstream links Uplink Failure Detection UFD 1627 ...