1.1
Detailing The Specifications
Electrical Specifications
Power requirements:
Supplied by the common equipment
Ringing voltage:
55 VAC Nominal @ 20 Hz
(45 VAC minimum)
Power rated to maximum
REN = 2.0
Battery feed voltage:
24 VDC nominal
Loop current limits between ATI-D and IST interface:
20 ma min. at 620 ohms
70 ma max. at 0 ohms
DC loop limits from ATI-D to industry standard
interface per port:
620 ohms maximum including interfaced
telephony device (Approximately 4000 feet with
#26 AWG twisted-pair cable and 300 ohm
device load.)
(Approximately 500 feet if two IST devices are
connected in parallel on same tip and ring pair.)
Cable insulation resistance:
30,000 ohms minimum
Cable requirement ATI-D to common equipment:
2-pair twisted cable; 25 feet maximum length.
(Both common equipment station ports must
always be connected to the ATI-D for every
installation.)
Cable terminations:
623-type, 4-conductor minijacks
Dialing:
Industry-standard DTMF or
Dial pulse (rotary) with nominal
make/break ratio of 40/60 @ 10 PPS
IMI89–208
Installing And Programming For ATI–D–1PT
2 – Installing The ATI–D–1PT
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...