6.0 Making The AC Power Connection
•
For the main cabinet’s AC power connection, employ a dedicated 15 AMP circuit, with a third-wire ground and
supplied to a standard electrical outlet. Remember, this electrical outlet must be located within four feet of the
common equipment cabinet. Remember also, you may need to supply two 15 AMP dedicated electrical outlets,
each protected by its own circuit breaker, if you plan to later install expansion cabinets.
NOTE: If you install the optional battery back-up assembly, you can use this same outlet to supply AC power to
that assembly’s battery charger.
•
To provide protection against surges and spikes that may appear on the AC line, install a plug-in power line
surge protector between the AC power cord of the installed equipment and the AC outlet..
CAUTION
DO NOT attach or secure the line cord to the surface of the mounting location in any manner.
Plug-In
Power Line
Surge Protectors
Typical Earth
Ground
Power
Cable
Two Dedicated
117 VAC 15 Amp
NEMA 5-15R
Electrical Outlets
With Third Wire
Ground
(Each Is Protected
By Its Own Circuit
Breaker.)
PLUS038
Two 15 AMP
Circuit Breakers
Ganged Together
Making The AC Connection
Installing The Switchable Power Supply
IMI89–196
Installing The Switchable Power Supply – 7
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...