6.0 Configuring The Common Audible Ringing Interface
The services board provides relay actuation dry-contact terminals that you can use for controlling external ringing
equipment. These relays are under programming control. You can program them to provide dry-contact
actuations that track the ringing pattern of any of the programmed flexible ringing assignment ringing patterns.
CAUTION
Do not exceed a 1 amp at 24 volts (0.5 amp at 48 volts) load on these control terminals. If the load
requirements exceed this limit, connect the load through an external slave relay. DO NOT CONNECT
THESE CONTROL TERMINALS DIRECTLY TO THE 120VAC LINE.
Detailing Typical Common Audible Interface Wiring
PLUS063
Front View Of Jacks
Common Audible Interface Relays
Relay
Jack
J3
J4
Pin
No.
1
1
2
2
3
3
4
4
5
5
6
6
No Contact
No Contact
No Contact
No Contact
Relay 1
Relay 2
Relay 2
Relay 1
Relay 3
Relay 3
Relay 4
Relay 4
Signal
Relay 1
Relay 3
Relay 2
Relay 4
Services
Board
(Wiring shown for low current application - see caution text)
Wire to
Common
Audible
Interface
Relay
Wire to
Common
Audible
Interface
Relay
Signalling
Device
Signalling
Device
Power
Source for
Signalling
Device
AC or DC
Input as
Required
AC or DC
Input as
Required
AC or DC
Input as
Required
24V @ 1A Max.
48V @ .5A Max.
24V @ 1A Max.
48V @ .5A Max.
(Wiring shown with slave relay connection for high current application - see caution text)
Power
Source for
Slave
Relay
Voltage Clamping Diode
Recommended
Slave
Relay
Power
Source for
Signalling
Device
CAJS007
1
2
3
4
5
6
1
2
3
4
5
6
Installing The DXP Plus Main Cabinet
IMI66–105
Installing The DXP Plus Main Cabinet – 19
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...