3.3
Detailing Station Call Announce Parameters
The DXP Plus systems place no limits (other that the distance constraints stated previously) on telephone
placement and arrangement within the system; however, when placing telephones that require call announcing
capability, consider the parameters detailed in this call announce matrix table.
Call Announce Matrix
Receive Call Announcements
Digital
Speaker
Digital
Monitor
Digital
Single
Line
Analog
Speaker
Analog
Monitor
Analog
Single
Line
PC
Atten.
Scout
900MX
Industry
Standard
Digital
Speaker
YES
YES
NO
YES
NO
NO
NO
NO
NO
Digital
Monitor
YES
YES
NO
YES
NO
NO
NO
NO
NO
Digital
Single
Line
YES
YES
NO
YES
NO
NO
NO
NO
NO
Analog
Speaker
YES
YES
NO
YES
YES
NO
NO
NO
NO
Analog
Monitor
YES
YES
NO
YES
YES
NO
NO
NO
NO
Analog
Single
Line
YES
YES
NO
YES
NO
NO
NO
NO
NO
PC
Atten.
YES
YES
NO
YES
NO
NO
NO
NO
NO
Scout
900MX
YES
YES
NO
YES
NO
NO
NO
NO
NO
Industry
Standard
YES
YES
NO
YES
NO
NO
NO
NO
NO
3.4
Understanding The DXP Plus Logical Numbering
Because there are no dedicated station or line ports in the DXP Plus, the system uses an automatic configuration
method to logically number its stations and lines. Automatic configuration occurs after you perform a master clear
on the system.
How automatic configuration works
With automatic configuration, the system does a search for all installed station and line boards in the main and
expansion cabinets, and assigns a logical number for each provided station and line encountered during the search.
The search begins in the main cabinet at the left-most universal slot and proceeds left to right. The search then
moves to the upper expansion cabinet where it searches left-most slot to right-most slot. The search finally moves
to the lower expansion cabinet where it again searches left-most slot to right-most slot. When automatic
configuration is finished, the system has logically numbered all station and line ports in ascending order from the
left-most slot to right-most slot throughout the entire system.
Originate
Call
Anno
unceme
n
ts
IMI89–173
Installing The Analog Station Board
10 – Installing The Analog Station Board
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...