Installing The T1/PRI Line Board
1. Normally you should disconnect the AC power cord from the AC outlet and disconnect the optional battery
back-up assembly from the main cabinet power supply; however, when necessary, you can install a T1/PRI
board in an operating system. If you must do this, connect one end of a standard telephone handset coil cord
to the pre-charge port on the power supply. During step 6, you will connect the other end of this coil cord to
the pre-charge jack on the line board.
2. Install your static discharge wrist strap on your bare wrist; adjust it for a snug fit. Be sure that the strap is
touching bare skin and is not isolated by clothing. Connect the wrist strap cord between the wrist strap and an
AC or earth ground
3. Loosen the retaining hardware and lift the front panel away from the common equipment cabinet.
NOTE: With the common equipment in the installed position, the ground lug on the side of the cabinet is an
appropriate grounding point since it should have a heavy ground wire connected between it and a good
earth ground.
4. Each board is supplied in a static protection bag for safe keeping. When you are ready to install the board,
remove it from its static protection bag.
5. Locate the proper board slot. On DXP Plus systems the T1/PRI board connects to any universal slot.
NOTE: On DXP Plus systems, do not install a T1/PRI board at the right-most board slot in the second (or lower)
expansion cabinet. The system reserves this slot for internal use.
6. If you are installing the board in an operating system, connect the free end of the pre-charge cord that you
installed in step 1 to the pre-charge jack on the line board.
7. Orient the board with its top and bottom guides in main cabinet board cage, and press the board firmly until
its board edge connection properly mates with the connector on cabinet’s backplane. If you connected a
handset cord between the pre-charge port on DXP Plus power supply and the jack on board (as directed in
step 6), disconnect it after installing board.
CAUTION
When pressing circuit boards into place, press them only at the extractor lever locations.
If you apply pressure at other locations you may damage the board assembly.
8. Repeat steps 3 and 4 until all boards are installed.
9. Make a final inspection to ensure that all boards are, oriented correctly and mated properly.
10. Install and tighten the supplied screws to secure the circuit boards to the board cage. Do not neglect this step!
It is important because it helps in providing a protective ground condition for the board thus ensuring RFI
(radio frequency interference) and lightning protection.
NOTE: If you ever find it necessary to field-install a DXPRI card on a T1 board, refer to the paragraph titled,
Up-grading Your DPT1 Board For ISDN–PRI Support, that is located at the end of this publication.
IMI89–255
Installing And Programming The DXPRI Card
20 – Installing The T1/PRI Line Board
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...