3.0 Installing The ExecuMail System
At Digital Station Ports
When you interface the ExecuMail system to the DXP Plus system through the digital station ports on its digital
station board, you must place the Analog Terminal Interface Device (ATI–D–1PT) between the two systems. The
ATI-D-1PT includes one circuit; therefore, you will need a separate device for every ExecuMail port that you
plan to connect. This means that for a four-port ExecuMail system, you will need four ATI–D–1PT
devices. The ATI–D–1PT is powered through its station port connections.
3.1
Installing The ATI-D-1PT
Be sure the mounting location is secure and dry, has adequate ventilation, and is a large enough area to allow easy
placement of the ATI–D–1PT. The temperature range of the location must be within 32 - 90° F (0 - 40° C).
Be sure that you have the following tools and hardware available for mounting the ATI–D–1PT:
•
Fasteners, such as 1/4-inch wood screws, of a sufficient length to securely bite into mounting backboard
•
Cross Recessed screwdriver (phillips-head type)
•
Flat-blade Screwdriver
•
Electric Drill if prepared holes are needed
•
Connecting tool - for fastening wires to a type-66 connector block.
•
Crimping tool - for 623-type modular plugs.
1. Unpack, and carefully inspect the ATI–D–1PT for shipping damage. Notify the shipper immediately of any
damages found. Verify that the package contains all parts and accessories needed for proper installation and
operation.
2. Locate the device within 25 feet of both the common equipment cabinet and the ExecuMail system.
1. If a backboard is required at the mounting location, attach it securely to provide a stable mounting surface.
2. Use the base of the ATI–D–1PT cabinet as a template or measure for mounting hole locations per the
dimension details shown in the outline dimensions drawing located on the next page.
3. Drill holes of a proper size to accommodate the hardware being used into the mounting surface. If necessary,
prepare these holes with inserts, anchors or other attachment devices as dictated by the type of mounting
surface.
4. Insert the two top screws into the mounting surface and tighten them to within approximately 1/8-inch of the
surface.
5. Hang the ATI–D–1PT cabinet on the top screws using the mounting holes located on the rear of the cabinet.
Note that these holes are elongated with an enlargement at one end. This feature allows the cabinet to snap
down on the screws to secure the mounting when the cabinet is hung on them.
6. Insert a third screw through the mounting tab located on the lower edge of the cabinet and into the mounting
surface; tighten it into place.
IMI89–206
Installing And Programming For ExecuMail
6 – Installing And Programming For ExecuMail
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...