3.1
Understanding The DXP Plus Logical Numbering
Because there are no dedicated station or line ports in the DXP Plus, the system uses an automatic configuration
method to logically number its stations and lines. Automatic configuration occurs after you perform a master clear
on the system.
How automatic configuration works
With automatic configuration, the system does a search for all installed station and line boards in the main and
expansion cabinets, and assigns a logical number for each provided station and line encountered during the search.
The search begins in the main cabinet at the left-most universal slot and proceeds left to right. The search then
moves to the upper expansion cabinet where it searches left-most slot to right-most slot. The search finally moves
to the lower expansion cabinet where it again searches left-most slot to right-most slot. When automatic
configuration is finished, the system has logically numbered all station and line ports in ascending order from the
left-most slot to right-most slot throughout the entire system.
How logical number and physical location relate to one another
The logical number of a station or line corresponds to its relationship to other stations or lines in the system but is
not dependent upon the board’s placement in the cabinet. The physical location of a station or line corresponds to
the order of the system’s board slots. The main cabinet contains slots 1–9, the upper expansion cabinet contains
slots 10–20, and the lower expansion cabinet contains slots 21–30. Therefore, even if the first encountered station
board is located in slot five of the main cabinet, the system still assigns logical number one to the first station
provided by that board. During installation, you can skip slots. For example, you can install eight-line, loop start,
line boards in only slots one and 30 if you wish. In this case, slot one yields logical line numbers 1–8 and slot 30
yields logical line numbers 9–17.
Where you can place circuit boards
Each installed board requires timing circuits equal to its capacity. For example, a 16–station board requires 16
timing circuits, an eight–line loop start line board requires eight circuits, and a fully configured T1 trunk board
requires 24 timing circuits. In the DXP Plus, each universal slot provides 32 timing circuits. Because of this
timing circuit provision of each slot, you can place any station or line board at any slot location with no
restrictions.
Adding boards without renumbering
If you install or relocate a station or line board, this board does not operate until you take appropriate
programming action. If you use an available open slot for adding or relocating a board, that board’s stations or
lines assume logical numbers in sequence after the system’s last assigned logical station or line number. For
example, if the system’s last logical station number is 24, the logical numbers of the newly installed board’s
stations begin at logical number 25.
After you remove a board and delete it through programming, that board’s logical numbers are available for
reassignment. This means that you can remove a board, add or move another board, take the appropriate
programming action, and have the stations or lines of the added or relocated board assume the logical numbers
made available by the removed board. For example, if the system’s last logical number is 64 and you remove the
board providing stations with logical numbers 1–16 and delete it through programming, the stations on an added
board assume logical numbers beginning with 1 instead of 65. However, if you remove and program delete an
eight-station board and add a 16-station board, the first eight stations stations on the added board assume logical
numbers 1–8 and the last eight stations assume logical numbers 65–72.
Remember, should you master clear the system, the automatic configuration feature logically numbers all station
and line ports in ascending order from the left-most slot to right-most slot throughout the entire system. This
action renumbers those station and lines provided by boards that you have added or relocated since you last
performed the system master clear.
IMI89–191
Installing The DID Line Board
10 – Installing The DID Line Board
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...