8.1.9
Dialing Mode
Description:
Program the line port to match either a
tone or a rotary (pulse) dialing line as supplied
by the central office (CO).
Programming:
1. Press CONTROL T for main menu.
2. From main menu, select lines and press ENTER.
3. From lines menu, select line programming and press ENTER.
4. Type line port number (l-240) or name and press ENTER.
5. From line programming menu, type item number for feature and press ENTER.
6. Press SPACE bar for feature setting and press ENTER to accept setting.
7. When finished, press ESCAPE twice.
8. Type y to accept changes, n to reject them, or r to resume editing
and press ENTER.
9. Repeat steps 4-8 for each line port or press ESCAPE to end.
Pulse Dial Make/Pulse Dial Break
(Pulse Dial Ratio)
Description:
With pulse dialing enabled, use this procedure to set the make/break ratio for rotary dial
signalling to match rotary dial line requirements. You can set the line make/break ratio for
rotary dial (pulse dial) signalling in a more flexible manner to match many different rotary dial
line requirements. You can set the make time and the break time independently in one msec.
increments to any time from one to 99 msec.
Programming:
1.
2 .
3 .
4 .
5 .
6 .
7 .
8 .
9 .
Press CONTROL T for main menu,
From main menu, select system and press ENTER.
From system menu, select timing and press ENTER,
From timing menu, type item number for line pulse make and press ENTER.
Type desired time (l-99) and press ENTER,
From timing menu, type item number for line pulse break and press ENTER.
Type desired time (l-99) and press ENTER.
Press ESCAPE twice,
Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
Pulse Dial Interdigit Time
Description:
with pulse dialing enabled, you can set the interdigit time between dial pulses when the system
pulse-dials a number over a line. The system defaults this time to 200 msec. and provides a
range of timing values between 100 msec. and one sec. that you can set in 100 msec. increments.
Programming:
1. Press CONTROL T for main menu,
2. From main menu, select system and press ENTER.
3. From the system menu, select timing and press ENTER.
4. From timing menu type item number for feature and press ENTER.
5. Press SPACE bar to select desired time and press ENTER to select setting.
6. Press ESCAPE twice,
7. Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
Line Features
Programming 8-7
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...