NOTE: Under BOARD CONFIGURATION/CABINET VIEW, the VMMI graphically shows the boards
installed in the arrangement that you specified and leaves a blank slot for any place that you
answered a station or line board prompt with a no board response
(c) A prompt asks that you confirm that conversion has taken place by clicking
OK
.
7. Select
Open As . . .
.
8. Select the file name that you specified in step 4 and
OK
you selection.
9. Specify the destination revision and destination platform for the translated database and
OK
your
specification. Database translation now occurs.
10. From the
File
drop-down menu, select
SAVE
.
11. Check the translated results, and under BOARD CONFIGURATION/CABINET VIEW, use your mouse to
move the board images to match your plan for the upgraded system. Remember, you must physically move
the boards in the common equipment cabinet to match the arrangement that you set with the VMMI program.
Master Clearing The DXP System
To insure that the DXP will perform properly with the new memory card, master clear the system. The
DXCPU–68K board provides a method for the master clear to occur automatically at the initial power up
after you have changed or upgraded the software card.
CAUTION
A master clear operation erases an existing database. If you wish to preserve the existing
database, you must archive it before you master clear the system. You can then restore this
database after you master clear the system. Remember, if this database is not at software release
10A or later, you must convert and translate it.
Execute the following sequence of events exactly as they are stated here:
1. On the DXPCPU–68K circuit board, set DIP switch 8 to its ON position.
2. Connect the DXP’s AC power cord to the AC outlet and turn on the AC power switch. At power up, the DXP
automatically executes a master clear operation. After the master clear sequence is complete, the indicators on
the DXCPU–68K and DXSRV boards turn on steady and the indicators on the station and line boards wink
ON for four seconds and OFF for four seconds. The system performs the automatic master clear one time
following the initial power up after you have upgraded the software. It will not perform an automatic master
clear operation again after subsequent power ups.
3. You can leave DIP switch 8 ON or you can turn it OFF. Leaving it ON will ensure that the DXP will always
power up in a master cleared and operational mode after a software upgrade. Turning it off prevents the DXP
from becoming operational at power up after a software upgrade. The OFF setting may be acceptable because,
should you forget to save your database, you have an opportunity to reconsider your actions before the DXP
erases the current database.
Upgrading The DXP Software – 21
Programming The Features
GCA40–219
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...