4.0 Testing The Digital Station Installation
4.1
Making A Resistance Check
Measure the resistance at the station connector blocks under the following conditions.
•
AC power cord disconnected from electrical outlet.
•
Common equipment connected to station connector blocks.
•
Stations wired and wiring punched down on blocks.
•
Bridging clips removed from blocks to isolate stations from common equipment.
Measure the resistance of each installed station and wiring from the station side of the connector blocks.
Resistance values will vary with cable length and station type but should be within the following limits:
4 Greater than 700 Kohms
Measure the resistance of the common equipment and cables from the common equipment side of the station
connector blocks. The resistance value should be within the following limits.
4 40–50 Ohms
4.2
Making A Voltage Check
Make the following voltage measurements at the station connector blocks under the following conditions:
•
Bridging clips installed
•
AC power connected to the common equipment
Measure the voltage across the signal pair. The measured voltage must be within the following limits:
4 28–36 VDC
4.3
Causing A Digital Station To Self Test
The multiline stations can be self tested for proper operation per the following instructions:
1. Disconnect line cord at station base.
2. Press and hold MUTE and reconnect line cord to station connector. Station will automatically perform self
test routine.
3. Release MUTE as soon as test begins. Sequence of test is as follows:
•
(a.) Indicators will light in sequence
•
(b.) Ringer will sound - be sure volume is set to low or high
•
(c.) Indicators and ringer will then turn off at the same time
4. Replace any station that does not pass the self test.
Installing The Digital Station Board
IMI89–174
Installing The Digital Station Board – 11
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...