Power Supply Measurements
Measure Between Terminals
Measured Values
+ Voltmeter
Lead
- Voltmeter
Lead
Pin 1
Pin 3
- 36 VDC +1.0V / -0V
Pin 5
Pin 7
+ 5 VDC +/-3 V
Pin 6
Pin 7
- 5 VDC +/-3 V
Pin 8
Pin 7
0 volts = normal operation
+ 5 V nominal = thermal overload
(press reset switch)
On = -36 VDC
On = +5 VDC
On = -5 VDC
On = Thermal Overload
On = Battery Backup Connected
Pins 1 & 2 = -36 V Ground
Pins 3 & 4 = -36 VDC
Pin 5 = +5 VDC
Pin 6 = -5 VDC
Pin 7 = Digital & Analog Ground
Pin 8 =Thermal Overload Signal
PLUS070
On/Off Switch
Fuse
6.3A, 250V
Slow Blow
Type
Reset Switch
(Press If Thermal Overload
Indicator Turns On)
Source Voltage Switch
Measuring The Power Supply Voltages
Installing The Switchable Power Supply
IMI89–196
Installing The Switchable Power Supply – 9
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...